[vc_row css=”.vc_custom_1452687555475{margin-bottom: 100px !important;}”][vc_column offset=”vc_col-lg-9 vc_col-md-9″ el_class=”casestudy_detail”][vc_custom_heading source=”post_title” use_theme_fonts=”yes” css=”.vc_custom_1629788606766{margin-bottom: 15px !important;}”][vc_column_text css=”.vc_custom_1629788850697{margin-bottom: 0px !important;}”][/vc_column_text][vc_row_inner css=”.vc_custom_1453271494452{margin-bottom: 50px !important;}”][vc_column_inner width=”1/2″][vc_single_image source=”featured_image” img_size=”395×256″][/vc_column_inner][vc_column_inner width=”1/2″][vc_custom_heading text=”Velosi conducted a Risk-Based Inspection (RBI) Study for KNPC Clean Fuel Project MAA Package located in Kuwait in order to assure asset integrity resulting in substantial cost savings and therefore to reduce the risks to Mina-Al-Ahmadi Refinery’s operational objectives.” font_container=”tag:div|font_size:16px|text_align:left|color:%23444444|line_height:26px” google_fonts=”font_family:Poppins%3A300%2Cregular%2C500%2C600%2C700|font_style:600%20semi-bold%3A600%3Anormal” css=”.vc_custom_1639727441510{margin-bottom: 18px !important;}”][/vc_column_inner][/vc_row_inner][vc_separator color=”custom” accent_color=”#dddddd” css=”.vc_custom_1453271595991{margin-bottom: 21px !important;}”][vc_row_inner css=”.vc_custom_1453271763899{margin-bottom: 33px !important;}”][vc_column_inner width=”1/4″ css=”.vc_custom_1453272656287{padding-right: 45px !important;}”][vc_custom_heading text=”Objective” font_container=”tag:h3|font_size:24px|text_align:right|color:%23222222|line_height:30px” use_theme_fonts=”yes”][/vc_column_inner][vc_column_inner width=”3/4″ css=”.vc_custom_1453271259318{padding-top: 18px !important;}”][vc_column_text]

  • Conduct a Risk-Based Inspection (RBI) Study in order to assure asset integrity and therefore to reduce the risks to JGSK’s Mina-Al-Ahmadi Refinery’s operational goals.
  • Perform the effective application of RBI principles to reduce unplanned equipment failures and associated plant shutdowns.

[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_separator color=”custom” accent_color=”#dddddd” css=”.vc_custom_1453271595991{margin-bottom: 21px !important;}”][vc_row_inner css=”.vc_custom_1453272927441{margin-bottom: 33px !important;}”][vc_column_inner width=”1/4″ css=”.vc_custom_1453270747989{padding-right: 45px !important;}”][vc_custom_heading text=”Scope of Work” font_container=”tag:h3|font_size:24px|text_align:right|color:%23222222|line_height:30px” use_theme_fonts=”yes”][/vc_column_inner][vc_column_inner width=”3/4″ css=”.vc_custom_1453271259318{padding-top: 18px !important;}”][vc_column_text]

  • Carry out Shell RBI (Level-3) assessment for 38 New (Process/ Utility) units, and 41 Revamp and Tie-In (Process/ Utility) units, at construction stage and As-Built stage. It also comprised to ensure the usage of Shell RRM software in the linkage of risks with appropriate inspection, process control or other risk mitigation activities.

[/vc_column_text][/vc_column_inner][/vc_row_inner][vc_separator color=”custom” accent_color=”#dddddd” css=”.vc_custom_1453271595991{margin-bottom: 21px !important;}”][vc_row_inner][vc_column_inner width=”1/4″ css=”.vc_custom_1453270747989{padding-right: 45px !important;}”][vc_custom_heading text=”Deliverables” font_container=”tag:h3|font_size:24px|text_align:right|color:%23222222|line_height:30px” use_theme_fonts=”yes”][/vc_column_inner][vc_column_inner width=”3/4″ css=”.vc_custom_1453271259318{padding-top: 18px !important;}”][vc_column_text]

Velosi submitted the following deliverables:

  • Risk Based Inspection (RBI) Study:
    • Risk Based Inspection Methodology/Execution Procedure
    • Corrosion Loop Drawings over PFS and PEFS
    • Optimized Inspection Plan
    • Corrosion Risk Assessment Summary Report
    • Risk Management with Inspection Activities
    • Data population in Shell RRM software
    • API 650 Tank Assessment Results from Tank RRM Module.
    • Corrosion Loop Smart Sketch

[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][vc_column width=”1/4″ offset=”vc_hidden-sm vc_hidden-xs”][stm_sidebar sidebar=”619″][/vc_column][/vc_row][vc_row full_width=”stretch_row” el_class=”third_bg_color” css=”.vc_custom_1451889219674{margin-bottom: -60px !important;}”][vc_column][vc_cta h2=”Let us help you to provide the best solution for your asset !” h2_font_container=”tag:h2|font_size:20px|text_align:left|color:%23000000|line_height:24px” h2_use_theme_fonts=”yes” shape=”square” style=”flat” add_button=”right” btn_title=”Contact Us” btn_style=”flat” btn_color=”theme_style_2″ btn_align=”right” btn_i_align=”right” btn_i_icon_fontawesome=”fas fa-chevron-right” particles=”yes” use_custom_fonts_h2=”true” btn_button_block=”true” btn_add_icon=”true” el_class=”third_bg_color” css=”.vc_custom_1629525637669{margin-bottom: 0px !important;}” btn_link=”url:https%3A%2F%2Fvelosiaims.com%2Fcontact-us%2F|title:Contact%20us”][/vc_cta][/vc_column][/vc_row]